PMS Cooling tower with open circuit

PMS Series
Potential power from 18 to 480 kW

Single-cell cooling tower with axial ventilator, body made from glass-fibre-reinforced polyester resin.
The tower packing inserts for the heat exchange and the mist eliminator are made from PVC, as are the water distributor, the drainage nozzles and the overflow pipe. The full-cone nozzles are made from polypropylene and are clog-free. The splash guard screens are made from fibre-glass.

There are 13 models available with a potential power of approx. 18 to 480 kW (power as a guideline with temperature drops of 5 °C).

The PMS Series cooling towers are made completely from fibre-glass and are thus corrosion-resistant. The use of plastic results in a low weight and means that the plant can be installed anywhere.

DESIGN:
– single-cell cooling tower with axial ventilator
– Body made from glass-fibre-reinforced polyester resin
– 13 models available

Directly coupled axial ventilator system, low energy consumption, low noise level

Body and trough made entirely from fibre-glass, corrosion-free

PVC distribution system with clog-free polypropylene nozzles with large openings

Tower packing with large opening (20 mm profile), suitable for use with industrial water

Manhole or detachable side wall

Protective grille and screws in stainless steel

Outer shell

(body, nozzle cap and trough optional) made entirely from glass-fibre-reinforced polyester resin, self-supporting structure with exclusive design and UV-protective Gelcoat coating.

Splash guard screen

made from glass-fibre-reinforced polyester resin by means of a pultrusion process (only in the version with the trough).

Inspection window

Round with a polyamide body and a polycarbonate window, which can be easily opened for an inspection of the inside of the cooling tower.

Tower packing

(cooling or heat exchange sheets) are made from self-extinguishing, decay-resistant PVC sheets, thermoformed under vacuum and then glued together. This tower packing is of the optimal form, composition and dimensions for contact with air/water inside the tower and for the corresponding heat exchange.

Mist eliminators

are made from self-extinguishing, decay-resistant PVC sheets, thermoformed under vacuum and then glued together. The form and dimensions of the sheets are designed as such that the transference of water droplets via the ventilator flow is kept to a minimum.

Supporting structure

for the tower packing and mist eliminator (if present) in hot-dip galvanised steel.

Water distribution system

with standardised pipes and PN 10 connections in PVC, consisting of a main collector with one or more threaded connections for the attachment of spray nozzles. The system is designed in such a way that the even and homogeneous distribution of the water to be cooled to the tower packing is guaranteed.